SPECIFICATIONS
- Wetted Parts SS316L
- Maximum Operating Temperature: upto 310°C
- Maximum Operating Pressure: 92 Kg/cm²
- Hydraulic Tested at: 140 Kg/cm²
- Level Point Measurement: 1 Point
- Liquid Conductivity: Minimum 5us/cm
- Probe Length: 500 / 1000 / 1500 mm
- Connection: 3/4” BSP screwed or flanged IBR approved
- Mounting Position: Vertical on standpipe / Shell / Vessel
- To be used with electronic liquid level controller series: CS05LQ / CS10LQ
APPLICATION
- High pressure High Temperature Thermosyphon level control
- High pressure Shell level control
- High pressure tank level control
ACCESS MANUAL REQUEST MORE INFORMATION